Subdivision

Concept Plan

4-SC-11-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 & 2 because the site's topography and natural features restrict compliance with the Subdivision Regulations.
APPROVE the concept plan subject to 4 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Placing a note on the final plat that all structures will have to be located at least 50' from the top of the sinkholes (closed contour area) identified on the plat. Construction within the 50' setback may be permitted if a geotechnical study prepared by a registered engineer states that building within the 50' sinkhole buffer is acceptable and the study is approved by the Knox County Department of Engineering and Public Works. Building construction is not permitted within the hatchered contour area of the sinkhole or 5' sinkhole easement. Engineered footings may be required for any structures within the 50' sinkhole buffer.
3. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.

Applicant Request

+
Subdivision
Campbell Station Villas - Phase 2
Lots
13 (Split)
Proposed Density
2.39 du/ac
Residential?
Yes - SF

Variances

1. Horizontal curve variance on Ridgeland Dr. at STA 4+50, from 250' to 125'.
2. Right-of-way dedication variance from the centerline of N. Campbell Station Rd., from 50' to 30'.


Property Information

+
Location
Northeast side of N. Campbell Station Rd., east end of Ridgeland Dr.

Commission District 6
Census Tract 59.01


Size
5.44 acres

Sector
Northwest County

Currently on the Property
Subdivision under construction

Growth Plan
Urban Growth Area (Outside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variances 1 & 2 because the site's topography and natural features restrict compliance with the Subdivision Regulations.

APPROVE the concept plan subject to 4 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Placing a note on the final plat that all structures will have to be located at least 50' from the top of the sinkholes (closed contour area) identified on the plat. Construction within the 50' setback may be permitted if a geotechnical study prepared by a registered engineer states that building within the 50' sinkhole buffer is acceptable and the study is approved by the Knox County Department of Engineering and Public Works. Building construction is not permitted within the hachured contour area of the sinkhole or 5' sinkhole easement. Engineered footings may be required for any structures within the 50' sinkhole buffer.
3. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
Disposition Summary
APPROVE variances 1 & 2 because the site's topography and natural features restrict compliance with the Subdivision Regulations.
APPROVE the concept plan subject to 4 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Placing a note on the final plat that all structures will have to be located at least 50' from the top of the sinkholes (closed contour area) identified on the plat. Construction within the 50' setback may be permitted if a geotechnical study prepared by a registered engineer states that building within the 50' sinkhole buffer is acceptable and the study is approved by the Knox County Department of Engineering and Public Works. Building construction is not permitted within the hatchered contour area of the sinkhole or 5' sinkhole easement. Engineered footings may be required for any structures within the 50' sinkhole buffer.
3. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.