Subdivision

Concept Plan

8-SD-14-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 & 2 because the existing site conditions restrict compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 9 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works
3. Dedicate 30' from the center line of Snyder Rd. for right-of-way as required by the Major Route Plan
4. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept., of Environment and Conservation
5. Constructing a temporary turn around at the terminus of Road A as directed by the Knox County Dept. of Engineering and Public Works
5. Prior to certification of the final plat, establish a homeowners association for the purpose of assessing fees for the maintenance of the storm drainage facilities, joint permanent easement and any other commonly held assets.
6. Place a note on the final plat that all access is to provided from the internal road system only
7. Prior to final plat approval obtain an off-site drainage easement if required by the Knox County Dept. of Engineering and Public Work
8. Approval of the rezoning of this site to PR (Planned Residential) by the Knox County Commission at a density of 3.56 du/ac or greater
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Letsinger Ridge
Lots
24 (Split)
Proposed Density
3.56 du/ac
Residential?
Yes - SF

Variances

1. Cul-de-sac bulb radius from 50' to 40'
2. Reverse curve tangent and broken back curve variance on Road A between sta 3+00 and sta 5+00


Property Information

+
Location
10922 Snyder Rd

Southeast side of Snyder Rd., northeast of Hunters Green Rd.

Commission District 6
Census Tract 59.04


Size
6.74 acres

Sector
Northwest County

Currently on the Property
3 detached dwellings and vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 & 2 because the existing site conditions restrict compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 9 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works
3. Dedicate 30' from the center line of Snyder Rd. for right-of-way as required by the Major Route Plan
4. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept., of Environment and Conservation
5. Constructing a temporary turn around at the terminus of Road A as directed by the Knox County Dept. of Engineering and Public Works
5. Prior to certification of the final plat, establish a homeowners association for the purpose of assessing fees for the maintenance of the storm drainage facilities, joint permanent easement and any other commonly held assets.
6. Place a note on the final plat that all access is to provided from the internal road system only
7. Prior to final plat approval obtain an off-site drainage easement if required by the Knox County Dept. of Engineering and Public Work
8. Approval of the rezoning of this site to PR (Planned Residential) by the Knox County Commission at a density of 3.56 du/ac or greater
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 & 2 because the existing site conditions restrict compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 9 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works
3. Dedicate 30' from the center line of Snyder Rd. for right-of-way as required by the Major Route Plan
4. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept., of Environment and Conservation
5. Constructing a temporary turn around at the terminus of Road A as directed by the Knox County Dept. of Engineering and Public Works
5. Prior to certification of the final plat, establish a homeowners association for the purpose of assessing fees for the maintenance of the storm drainage facilities, joint permanent easement and any other commonly held assets.
6. Place a note on the final plat that all access is to provided from the internal road system only
7. Prior to final plat approval obtain an off-site drainage easement if required by the Knox County Dept. of Engineering and Public Work
8. Approval of the rezoning of this site to PR (Planned Residential) by the Knox County Commission at a density of 3.56 du/ac or greater
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Letsinger Ridge

Eric Moseley


Case History