Subdivision

Concept Plan

5-SP-04-C

Recommended for approval
by the Planning Commission

APPROVE variance 1-4 because the site's topography restricts compliance with the Subdivision Regulations and the variances will not create a traffic hazard

APPROVE the concept plan subject to 7 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2.. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
3. Meeting all requirements of the previously approved concept plans for Cascade Falls (10-SH-03-C & 2-SG-04-C)..
4. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County, Ord. (91-1-102)
5. Meeting all requirements of the approved Use-on-Review development plan.
6. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
7. Final approval of the rezoning of this site to Planned Residential at a density that will accommodate the proposed development.

Applicant Request

+
Subdivision
Cascade Falls, Phase III
Lots
53 (Split)
Proposed Density
1.64 du/ac

Variances

1. Intersection grade variance from 1% to 3% at Roads D, E, & F.
2. Vertical curve variance on Road D at station 0+65 from 150' to 100'.
3. Vertical curve variance on Road D at station 3+72 from 454.25' to 250'.
4. Road grade variance from 12% to 13% on Road D from sta. 1+15 to sta. 2+35.89.


Property Information

+
Location
South side of Ball Camp Pike, east of Saint Gregory Ct.

Commission District 6


Size
32.40 acres

Sector
Northwest County

Currently on the Property
Vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variance 1-4 because the site's topography restricts compliance with the Subdivision Regulations and the variances will not create a traffic hazard

APPROVE the concept plan subject to 7 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2.. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
3. Meeting all requirements of the previously approved concept plans for Cascade Falls (10-SH-03-C & 2-SG-04-C)..
4. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County, Ord. (91-1-102)
5. Meeting all requirements of the approved Use-on-Review development plan.
6. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
7. Final approval of the rezoning of this site to Planned Residential at a density that will accommodate the proposed development.
Disposition Summary
APPROVE variance 1-4 because the site's topography restricts compliance with the Subdivision Regulations and the variances will not create a traffic hazard

APPROVE the concept plan subject to 7 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2.. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
3. Meeting all requirements of the previously approved concept plans for Cascade Falls (10-SH-03-C & 2-SG-04-C)..
4. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County, Ord. (91-1-102)
5. Meeting all requirements of the approved Use-on-Review development plan.
6. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
7. Final approval of the rezoning of this site to Planned Residential at a density that will accommodate the proposed development.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Cascade Falls, Phase III

Terry Patton


Case History