Subdivision

Concept Plan

5-SE-24-C

To be heard May 9, 2024Agenda Item No. 21

5-C-24-DP

Planning Staff Recommendation

Approve the Concept Plan subject to 7 conditions.


Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Westland Oaks
Lots
68 (Split)
Proposed Density
3.06 du/ac

Variances

VARIANCES
None

ALTERNATIVE DESIGN STANDARDS REQUIRING KNOXVILLE-KNOX COUNTY PLANNING COMMISSION APPROVAL
None

ALTERNATIVE DESIGN STANDARDS REQUIRING KNOX COUNTY ENGINEERING AND PUBLIC WORKS OR CITY OF KNOXVILLE ENGINEERING APPROVAL (PLANNING COMMISSION APPROVAL NOT REQUIRED)
1) Increase the maximum intersection grade from 1% to 3% at the intersection of Roads 'A' and Road 'B'.
2) Reduce the minimum right-of-way width from 50 ft to 40 ft on Roads 'A' and 'B.'
3) Reduce the minimum pavement width from 26 ft to 22 ft for Roads 'A' and 'B'.


Property Information

+
Location
9900 WESTLAND DR

West side of Ridge Climber Rd, west of Foot Path Ln

Commission District 5


Size
22.07 acres

Sector
Southwest County

Land Use Designation? LDR (Low Density Residential), HP (Hillside Protection), SP (Stream Protection)


Currently on the Property
Agriculture/Forestry/Vacant Land, Water

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
Approve the Concept Plan subject to 7 conditions.
1) Connection to sanitary sewer and meeting other relevant utility provider requirements.
2) Provision of street names consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3) Implementing the recommendations of the Westland Oaks Subdivision Units 1-3 Traffic Impact Study (Fulghum MacIndoe & Associates, Inc., August 24, 2020) as revised and approved by Planning and Knox County Engineering and Public Works staff (see Exhibit B). A Memorandum of Understanding with Knox County Engineering and Public Works for the completion of these road improvements is required per Chapter 54, Article V of the Knox County Code (Ord. O-23-4-102).
4) Providing a stream determination to Knox County Engineering and Public Works during the design plan phase. Any portion of that is determined to be a stream must be shown on the final plat with the required buffers.
5) All driveways must meet the standards of Article 3, Section 3.51 (Off-street parking lot layout, construction and maintenance) of the Knox County Zoning Ordinance.
6) Meeting all applicable requirements of the Knox County Department of Engineering and Public Works and the City of Knoxville Department of Engineering.
7) Before certification of the final plat for the subdivision, establish a property owners association or other legal entity responsible for maintaining common facilities, such as common areas, amenities, private roads, and/or stormwater drainage systems.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Westland Oaks

John Richard Patterson, PE


Case History